◊ Test I: The Research
|
Δ
|
In 1988, scientific research was done on the Schrijver systeem®. The research consisted
of two tests, and the results of the first test below shows excellent results. In this test the water saturation
of two test walls was registered for a period of 12 weeks. Both walls had been placed into containers for 3 weeks
to absorb water until the point of saturation was reached and the level of water absorption had dropped to a
minimum.
Table 1 shows a clear difference between wall A (with the Schrijver systeem®) and the wall without the system in
terms of relative humidity (RH).
|
Readings in the cavity
|
|
Date
|
|
Wall A
|
|
Wall B
|
|
Difference A & B in %
|
|
21 November
|
|
83% RH
|
|
95% RH
|
|
12% RH
|
|
19 December
|
|
62% RH
|
|
94% RH
|
|
32% RH
|
|
21 January
|
|
50% RH
|
|
82% RH
|
|
32% RH
|
|
Readings behind the cavity
|
|
Date
|
|
Wall A
|
|
Wall B
|
|
Difference A & B in %
|
|
21 November
|
|
42% RH
|
|
57% RH
|
|
15% RH
|
|
21 January
|
|
31% RH
|
|
49% RH
|
|
18% RH
|
table 1
graph 1
|
|
◊ Test II: Test Results
|
Δ
|
Every day throughout the test period, each element removed 339 ml of water in the wall
fitted with the Schrijver systeem® (wall A). Only 140 ml of water was removed from wall B without the system (see
table 2). (1000 ml is approx. 1/5 gallon). A difference of almost 200 ml per element per day!
The impact the Schrijver systeem® has on the relative humidity (RH) was also recorded (figure 2). Here the test
results were remarkable too. The RH in the enclosed space behind wall A where the Schrijver systeem® was located
was lower by 30% than the RH in the space behind the wall without the system. An outstanding result.
|
Date
|
Wall A
with Schrijver systeem®
|
Wall B
without Schrijver systeem®
|
Difference A & B in milliliters
|
|
28 October
|
0 mL
|
0 mL
|
0 mL
|
|
6 November
|
1350 mL
|
830 mL
|
485 mL
|
|
12 November
|
3000 mL
|
1720 mL
|
1280 mL
|
|
27 November
|
3649 mL
|
1000 mL
|
2649 mL
|
|
14 December
|
4600 mL
|
1850 mL
|
2750 mL
|
|
2 January
|
5300 mL
|
950 mL
|
4350 mL
|
|
total with wind
|
52123 mL
|
21539 mL
|
30584 mL
|
table 2
There is a clear difference between wall A and wall B. After 11 weeks and using only two elements, the
difference was more than 30 liters (6.6 gallons)! As the Schrijver systeem® works all year round, it will continue
to remove damp after the 11 week period, as it is an ongoing process.
|
|
Wall A
|
Wall B
|
Difference A & B in milliliters
|
|
total without wind
|
72 mL
|
9 mL
|
63 mL
|
table 3
Even without windy weather conditions, wall A with the Schrijver systeem® removes substantially more water than
wall B without the system installed.
graph 2
|
|
◊ Summary
|
Δ
|
The Schrijver systeem® is an essential factor in eliminating, preventing and controlling problems caused by damp.
The multifunctional results (dry walls and a decrease in the relative humidity within the house) brought about
this system, means that you can achieve a dry and healthy living environment and a substantial cut in heating
bills. Thanks to this system the building will be better preserved. The system requires little maintenance once
it's been installed. In short: a unique, environment friendly system, which you should not be without in a
countries such as the United Kingdom!
|
|